This prospective clinical study conducted in 2018 shows the ISQ (Implant Stability Quotient) measurement for four weeks after implant placement using Hiossen ETIII NH Implant. The following table shows the mean ISQ values of implants placed on the maxilla and mandible during the clinical study period. No implant failure or complication occurred. The high ISQ value of over 75 from implant placement indicates strong initial stability after implant placement. Throughout the osseointegration period of four weeks, the mean ISQ value improved with no stability drop.
The super-hydrophilic surface improved wettability, significantly increasing blood adhesion. During the remodelling phase, the nano apatite coating was absorbed and the newly formed bone was integrated into the SA surface. The results of this study demonstrate that Hiossen ETIII NH Implant greatly improves the healing process and supports functional loading after approximately four weeks.